Configuring The Rmon Ethernet Statistics Function; Configuring The Rmon History Statistics Function - HP 5500 EI Series Configuration Manual

Hide thumbs Also See for 5500 EI Series:
Table of Contents

Advertisement

A statistics object of the history group is the variable defined in the history record table, and the
recorded content is a cumulative sum of the variable in each period. For more information, see
"Configuring the RMON history statistics

Configuring the RMON Ethernet statistics function

Step
1.
Enter system view.
2.
Enter Layer 2 Ethernet
interface view or Layer 3
Ethernet interface view.
3.
Create an entry in the
RMON statistics table.
You can create one statistics entry per interface and up to 100 statistics entries on the device. When the
number of statistics entries exceeds 100, you cannot add new entries.

Configuring the RMON history statistics function

Follow these guidelines when you configure the RMON history statistics function:
The entry-number for an RMON history control entry must be globally unique. If an entry number
has been used on one interface, it cannot be used on another.
You can configure multiple history control entries for one interface, but must make sure their entry
numbers and sampling intervals are different.
On the HP 5500 SI switch, up to 100 history entries can be created. On the HP 5500 EI switch, up
to 1000 history entries can be created.
You can successfully create a history control entry, even if the specified bucket size exceeds the
history table size supported by the device. However, the effective bucket size will be the actual value
supported by the device.
To configure the RMON history statistics function:
Step
1.
Enter system view.
2.
Enter Layer 2 Ethernet
interface view or Layer 3
Ethernet interface view.
3.
Create an entry in the
RMON history control
table.
function."
Command
system-view
interface interface-type
interface-number
rmon statistics entry-number [ owner
text ]
Command
system-view
interface interface-type
interface-number
rmon history entry-number buckets
number interval sampling-interval
[ owner text ]
80
Remarks
N/A
You can configure an Ethernet port as
a Layer 3 Ethernet port only on the HP
5500 EI switch.
N/A
Remarks
N/A
You can configure an Ethernet port as
a Layer 3 Ethernet port only on the HP
5500 EI switch.
N/A