Step
5.
Configure the
destination port of
TCP probe packets.
6.
Configure the source
IP address of TCP
probe packets.
7.
Configure optional
parameters.

Configuring UDP echo tests

UDP echo tests of an NQA test group are used to test the connectivity and round-trip time of a UDP packet
from the client to the specified UDP port on the NQA server.
UDP echo tests require cooperation between the NQA server and the NQA client. Before you start UDP
echo tests, configure a UDP listening service on the NQA server. For more information about the UDP
listening service configuration, see
To configure UDP echo tests:
Step
1.
Enter system view.
2.
Enter NQA test group
view.
3.
Configure the test type as
UDP echo, and enter test
type view.
4.
Configure the destination
address of UDP packets.
5.
Configure the destination
port of UDP packets.
6.
Configure the size of the
data field in each UDP
packet.
Command
destination port
port-number
source ip ip-address
See
"Configuring optional
parameters for an NQA
test
group"
"Configuring the NQA
Command
system-view
nqa entry admin-name
operation-tag
type udp-echo
destination ip ip-address
destination port
port-number
data-size size
126
Remarks
By default, no destination port number is
configured.
The destination port number must be the same as
that of the listening service on the NQA server.
Optional.
By default, no source IP address is specified.
The source IP address must be the IP address of a
local interface. The local interface must be up.
Otherwise, no probe packets can be sent out.
Optional.
server."
Remarks
N/A
N/A
N/A
By default, no destination IP address is
configured.
The destination address must be the same as the
IP address of the listening service configured on
the NQA server.
By default, no destination port number is
configured.
The destination port number must be the same as
that of the listening service on the NQA server.
Optional.
100 bytes by default.