V45 :.~::!
THERMDSTATIC
S
WITCH
The cooling fan motor is actuated by the thermo-
static 5witch located in the left tank of the radiator.
Run the engine until coolant temperature reaches
88_92°C (191-197°F).
The fan motor should start running. The fan motor
should stop when the coolant temperature drops to
83-87°C (182-1B8°F).
SWI
TC HES
I
f
the fan motor does not
nart,
disconnect the black.
,
-
and green leads from the thermostatic switch and
short them together with a jumper wire as shown.
Turn the ignition switch on.
The cooling fan motor should start running.
If
it
starts, replace the fan thermostatic switch and
retest.
If it does not start, check for battery voltage from
thll black lead (positive)
t
o blacklblue (negative) of
the fan motor coupler.
If there is no lIoitage,
check
for a blown or faulty
fuse, loose terminals or connectors, and an open
circuit.
TEMPERATURE SENSDR
Disconnect the greenlblue wire from the tempera-
ture sensor.
Date of Issue: May, 1982
~
HONDA MOTOR
CO.,
LTD.
--------
-
-
\
JUMPER
WI
RE
TEMPERATURE SENSOR
/ '