Toshiba e-STUDIO350 Service Manual page 244

Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

(9) Remove 1 C-ring and take off the cleaning
roller with the whole bushings on both sides.
(10) Take off the bushings from the cleaning roller.
[H] Pressure roller
(1) Take off the cleaning unit (
[G]).
(2) Remove the pressure springs on both front
and rear sides.
(3) Pull out the pressure lever units on both left
and right sides.
(4) Take out the pressure roller.
13
[I]
IH coil
(1) Take off the fuser unit (
(2) Take off the fuser unit cover
(
Chapter 13.7 [B]).
(3) Release the harness from the harness guide
of the cover on the rear side.
(4) Remove 1 screw and take off the cover on
the rear side.
e-STUDIO350/450 FUSER UNIT / PAPER EXIT SECTION
Chapter 13.7
Chapter 13.7 [A]).
13 - 20
Fig. 13-717
Fig. 13-718
Fig. 13-719
Fig. 13-720
November 2003 © TOSHIBA TEC