Toshiba e-STUDIO350 Service Manual page 238

Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

(2) IH error
Checking timing
Power ON
In warming up
Detecting 40°C
In warming up
Detecting 40°C
During ready status
During ready status
During printing
At Energy Saving Mode
(2) IH error
Initial abnormality:
13
CPU (IH) abnormality is not cleared.
IH power voltage abnormality:
The input voltage becomes above 20% (approx.) or below 20% (approx.) of the rated voltage.
IGBT high temperature abnormality:
Overheating of IGBT or short- or open-circuit of IGBT temperature-detecting sensor.
IH circuit abnormality:
Abnormality in IH circuit
IH coil abnormality:
Temperature-detecting sensor in IH circuit is abnormal, or IH coil is open-circuited or wrongly in-
stalled.
e-STUDIO350/450 FUSER UNIT / PAPER EXIT SECTION
Error content
Initial abnormality
IH power voltage abnormality
IGBT high temperature abnormality
Continuous energization (15 sec.)
IH circuit/coil abnormality
IH power voltage abnormality
IGBT high temperature abnormality
Continuous energization (15 sec.)
IH circuit/coil abnormality
IH power voltage abnormality
IGBT high temperature abnormality
Continuous energization (15 sec.)
IH circuit/coil abnormality
Normal
13 - 14
Port input value
Error code
H1ERR1
H1ERR2
L
L
C470
L
L
C470
L
H
C480
H
H
C490
L
L
C470
L
H
C480
H
H
C490
L
L
C470
L
H
C480
H
H
C490
H
L
-
November 2003 © TOSHIBA TEC
Counter
10
11
12
13
14
15
16
17
18
19
-

Advertisement