Toshiba e-STUDIO350 Service Manual page 221

Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

Notes:
1.When installing the developer sleeve unit, make
sure that the side seals (urethane seal) of the
front and rear sides do not come out of the case.
2.When installing the doctor blade, make the gap
adjustment of the doctor sleeve.
[G] Mixer-1
(1)
Discharge the developer material
(
Chapter 12.5 (B-1)).
(2)
Take off the developer sleeve unit
(
Chapter 12.5 [F]).
(3)
Take off the bushing on the front side.
*Replacement of Oil Seal (
(4)
Remove 1 E-ring and 1 bushing. Then take
off the mixer-1.
[H] Mixer-2
(1)
Discharge the developer material
(
Chapter 12.5 (B-1)).
(2)
Take off the developer sleeve unit
(
Chapter 12.5 [F]).
(3)
Remove 1 E-ring and 1 bushing on the front
side.
(4)
Remove 1 screw and holder.
*Replacement of Oil Seal (
November 2003 © TOSHIBA TEC
Page 12-15)
Bushing
Bushing
Page 12-15)
12 - 13
Fig. 12-520
Oil seal
Fig. 12-521
Fig. 12-522
Holder
Oil seal
Fig. 12-523
e-STUDIO350/450 DEVELOPMENT SYSTEM
12
Bushing

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio450