MOTO GUZZI V-7 700 Operating Handbook page 114

Table of Contents

Advertisement

FAULTS
112
POSSIBLE CAUSES
Short·circuited ignition coil winding
(on
lest bed,
emmeter
shows absorption
to
to be
higher
than
normal).
Grounded Ignition coil primary winding
(current
flow does not stop even with
open
contact
breaker points).
Break
In Ignition
coil primary winding
(current
does not Ilow thru
coli).
Too wIde
or too
narrow contacls
gap.
Contact breaker arm seized
on
pin.
Short·circuited condensor.
REMEDIES
Replace ignition
call.
Replace ignition
call.
Replace
Ignillon
call.
Adjusl
to
correct gap and
tighten
down
screw whIch secures
fixed
contact
pta·
Ie. If
necessary
replace conlacts se\.
Remove conlact
breaker
arm.
Clean
pin and lubricate
with
a few
drops
of
suitable oil.
If necessary
replace con-
tact breaker
arm.
Replace
condensor.

Advertisement

Table of Contents
loading

Table of Contents