MOTO GUZZI V-7 700 Operating Handbook page 113

Table of Contents

Advertisement

FAULTS
Spark
failure.
POSSIBLE CAUSES
Contact breaker arm too tightly fitted
on its pin.
Lack of pressure at
contact
breaker
points.
Periodically
short-circuited condensor,
Jacking insulation or broken.
Break
in
connections.
Ignition coil cap perforated by
H.T.
or
grounded.
Distributor cap perforated by
H.T.
or
grounded.
Distributor rotor perforated
by
H.T.
or
grounded.
REMEDIES
Clean
and lubricate
pin
with few drops
01 suitable oiL
Check
and
if necessary replace contact
breaker
arm.
Check spring
load to be
as required by testing data.
Replece
condensor.
Locate
break and repair
or replace
connections.
Replace ignition coiL
Replace distributor
cap.
Replace distributor rotor.
111