FAULTS
11
0
POSSIBLE CAUSES
Ignition coli
wilh
short-circuited
or
broken
secondary winding (call supplies
very
weak
sparks).
Uncertain
L.T. connections.
Contact breaker
periodically
grounded
(current absorbed by primary winding
does not drop to zero when points
open).
Contact breaker points are
dirty,
oxi-
dater or
burnout.
Irregular gap of cont act breaker
points,
either due to excessive wear of same
(gap
too
wide) or
excessive
wear of
felt pad (gap too
narrow).
Contact
breaker points are out Of align-
ment.
REMEDIES
Rep lace Ignition coil.
Check
connections,
lighten screws and
nuts,
renew weklings
etc.
Check insulations and if necessary
re-
place them. Cl ean contact breaker plate
with pure gas.
Clean contact breaker points thoroughly
and If necessary smooth down surfaces
using suitable file.
Clean contact breaker points
tho
roughly
and adjust
gap.
If necessary replace
contact breaker
set.
AUgn points.
adjust
gap and tighten
down adjusting
screw.

Advertisement