Magiglo TRIBUTE PD-08-002 User, Installation & Servicing Instructions page 6

Table of Contents

Advertisement

Ventilation Requirements
1. This appliance does not require any ventilation in the room where it is fitted. It is a
balanced flue appliance whereby the air for combustion is drawn in from the outside and
the products of combustion are evacuated to the outside through a concentric flue duct
system.
2. In other EC countries equivalent rules in force must be used.
Gas Supply
1. This range of gas fires is suitable for use with Natural Gas (G20) at 20mbar supply
pressure.
2. A separate means of isolating the gas supply should be provided near to the appliance to
facilitate servicing. An isolation valve (with a pressure test point) has been supplied for
this purpose.
Electrical Supply
Not applicable to this range of appliances.
Efficiency Declaration
The efficiency of this appliance has been measured as specified in BS EN 613:2001 and the
results are 80% net. The gross calorific value of the fuel has been used for this efficiency
calculation. The test data from which it has been calculated has been certified by BSI Ltd. The
efficiency value may be used in the UK Government Standard Assessment Procedure (SAP)
for energy rating of dwellings.
Hot Surfaces
Certain parts of this appliance get very hot during normal use. It is therefore recommended
that a suitable fireguard be used for the protection of young children and the infirm. The
shaded parts in Figure 1 show the 'Working Surfaces' on the appliance.
Page 2
Masking Plate
All shaded portion is
working surface
Figure 1