3.4.

Technical Data

Nominal maximum heat input (hot)
Nominal minimum heat input (hot)
Setting pressures (cold) Max
Setting pressures (cold) Min
Gas Rate
Injector Size Multiport
Gas Inlet Connection
Pilot
Pilot Injector
Efficiency
Weighted NOx
Max / Min length of flue tube
Natural Gas (G20)
4.0 kW (gross)
2.3 kW (gross)
7.0 ±0.5 mbar
2.0 + 0.2 mbar
0.36 m3/h
7 x 0.77mm
8 mm Compression
Polidoro 440.0333.11
2 x 0.25mm holes
Class I
Class 4
1000 / 150mm
Table 1
ø
Page 13