Appliance Location - Magiglo TRIBUTE PD-08-002 User, Installation & Servicing Instructions

Table of Contents

Advertisement

3.5.

Appliance Location

The appliance is designed to be fitted through a non-combustible back panel and to be inset
into a cavity wall. Alternatively the appliance may be fitted into a false chimney breast, a deep
rebated fire surround or a defunct fireplace sited on an outside wall. The appliance may be
sited at floor level or as a raised 'hole in the wall' installation. If sited in an 'hole in the wall
Installation' provision must be made to stand the decorative fret upon.
In all installations we recommend a non-combustible back panel is used. We do not
recommend installing the appliance against a plastered wall without a back panel. The fire
must be fitted on a flat non-combustible base. In addition a non-combustible hearth with
minimum dimensions shown in figures below should be provided in front of the fireplace
opening where relevant. This is required to protect combustible floor coverings from radiant
heat from the fire. If the appliance is to be installed with its base more than 100mm above floor
level the hearth projection in front of the appliance may be reduced to the minimum required to
support the decorative fret (75mm).
Figure 17-Floor Level Opening
Figure 18 – Raised Level Opening
Page 14
Floor Level and Raised Fireplace Openings
Floor Level and
raised Level
Openings
OH
560mm
OW
420mm
OD
200mm
HD
Enough to support
decorative fret (75mm)
Table 2
L
L min - 320mm
L max - 1170mm
Figure 19