General Information - Magiglo TRIBUTE PD-08-002 User, Installation & Servicing Instructions

Table of Contents

Advertisement

1. G
ENERAL
Introduction
1. This appliance is suitable for installation in GB and IE and should be installed in
accordance with the rules in force.
In GB, the installation must be carried out by a Gas Safe Registered Installer. It must be
carried out in accordance with the relevant requirements of the:
·
Gas Safety (Installation and Use) Regulations.
·
The appropriate Building Regulations either The Building Regulations, The
Building Regulations (Scotland), Building Regulations (Northern Ireland).
Where no specific instructions are given, reference should be made to the relevant British
Standard Code of Practice (see item 2).
In IE, the installation must be carried out by a Competent Person and installed in
accordance with the current edition of I.S.813 "Domestic Gas Installations", the current
Building Regulations and reference should be made to the current ETCI rules for electrical
installation.
On completion of an installation in IE, it is necessary to complete a "Declaration of
Conformity" to indicate compliance to I.S.813.
2. The installation of the fire should also follow the recommendations of the following current
British Standards (or equivalent):
BS 6891
BS 5440: Pts 1 & 2
IGE/UP/7
3. In other EC countries equivalent rules in force must be used.
4. It is important for correct combustion of this fire that the imitation fuel is placed in
accordance with the instructions given in this and associated booklets. Only approved
imitation fuel, available from Burley Appliances Ltd., should be used with this appliance.
5. It is recommended that a fire guard complying with BS 8423 be fitted for the protection of
young children, the elderly or infirm.
6. Ensure that curtains are not positioned above the appliance and there is at least 300mm
between the sides of the appliance and any curtains.
7. Combustible shelves or materials must only be fitted above the fire in accordance with the
instructions given in this and associated booklets.
8. The user is warned not to remove the glass panel or to disturb the fuel bed.
9. If any cracks appear in the glass panel do not use the appliance until the glass
panel has been replaced (by a qualified installer).
10. Ensure that the flue terminal is always kept clear of any obstructions (e.g. shrubs, plants,
objects leaning against it, etc.).
11. It is important for the fire to be serviced regularly. An annual service is recommended.
I
NFORMATION
Pipe work Installation
Flues and Ventilation
IGE document for gas installations in Timber Frame Buildings
(Available from Institute of Gas Engineers and Managers)