Servicing Instructions; 4.1. General Requirements - Magiglo TRIBUTE PD-08-002 User, Installation & Servicing Instructions

Table of Contents

Advertisement

4. S
ERVICING

4.1. General Requirements

All repairs and servicing must be carried out by a qualified registered gas installer (e.g.
member of Gas Safe Register in GB) in accordance with the current Gas Safety (Installation
and Use) Regulations and these instructions.
Before any servicing is carried out ensure that the gas and electric supply (where applicable)
are turned off.
Always check for gas soundness after dismantling or exchange procedures.
CAUTION: Ensure that the appliance is off (including the pilot light) and has
completely cooled (off for at least 2 hours) before carrying out any cleaning or
maintenance.
RCF Advice:
This product may use Components (Coals, Pebbles & Ceramic backs)
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to this material may cause irritation to eyes,
skin and respiratory tract.
Therefore during installation and servicing we recommend that you use a HEPA
filtered vacuum to remove any dust and soot accumulated in and around the fire
before and after working on the fire, to ensure that the release of fibres from
these RCF articles is kept to a minimum.
We recommend that you should follow the normal hygiene rules of not smoking,
eating or drinking in the work area.
When replacing Components containing Refractory Ceramic Fibres (RCF), we
recommend that the replaced items are not broken up, but are sealed within
heavy duty polythene bags, and clearly labelled as RCF waste. RCF waste may
be disposed of in suitably licensed landfill sites.