Lighting Procedure (Remote Control) - Magiglo TRIBUTE PD-08-002 User, Installation & Servicing Instructions

Table of Contents

Advertisement

2.2.2.

Lighting Procedure (Remote Control)

1. Press the bottom button on the remote
handset until clicking is heard on the
valve, and the gas rate adjustment knob
is at the off position.
2. With gas available at the valve press the
IGNITION
KNOB
anticlockwise to the pilot flame position
(see Figure 7). A click of the piezo
igniter will be heard and a spark will
appear at the electrode. At the same
time the gas will flow to the pilot burner
and should be ignited by the spark.
Repeat the procedure until the pilot
flame is established.
3. Keep the knob pressed in for a further 15
- 20 seconds and slowly release it. The
pilot flame should stay alight. If the flame
goes out repeat the procedure above to
establish the pilot. Due to safety and the
efficient way the fire works, it is not
unusual for the pilot to stay alight only
after the second or even third attempt.
4.
5. Turn
the
anticlockwise to the Main Burner
Operation position as shown in Figure
7.
6. Using the HANDSET (as shown in
Figure 8) press and hold both the top
and the small button together until the
main burner goes to full rate and clicking
can be heard from the valve. During this
process the main burner will ignite from
the pilot.
7. By pressing the two buttons together (to
increase the gas rate) and the lower
button only (to decrease the gas rate)
the valve can be manipulated to select
the desired gas rate between maximum
and minimum. By pressing the buttons in
short bursts you will be able to adjust the
gas rate in small steps.
8. To turn the fire off, continuously press
the lower button until the flame dies
down and clicks can be heard from the
Page 6
in
and
turn
IGNITION
KNOB
valve. Release the button as soon as the
clicks are heard.
9. The fire can safely be left in this position
at
all
times,
unauthorised or accidental use (say by
it
children) it is recommended to turn the
IGNITION KNOB to the pilot flame
position
by
clockwise. To turn the pilot off, turn the
IGNITION KNOB fully clockwise.
NOTE:
made by the valve is the
operation of the valve clutch,
and indicates either maximum
or minimum positions.
GAS RATE
ADJUSTMENT
KNOB
Figure 7 – Gas Valve
Press these
two buttons
together to
increase
gas rate
Figure 8 - Handset Operation
however
to
prevent
turning
it
90
degrees
The
clicking
sound
FULL RATE
POSITION
PILOT ONLY
MAIN BURNER
POSITION
OFF POSITION
IGNITION
KNOB
MAIN BURNER
OPERATION
Press this
button to
decrease
gas rate

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents