Magiglo TRIBUTE PD-08-002 User, Installation & Servicing Instructions page 28

Table of Contents

Advertisement

Surround/
False Chimney
Breast
L
200mm
min
Base
Figure 32
11. Apply the fire cement supplied around
each of the duct spigots on the rear of
the appliance.
12. Push the two lengths of duct previously
cut on to the duct spigots. Make sure the
ducts are pushed fully home up to the
firebox.
13. Position the firebox complete with ducts
attached centrally into the fire opening.
Thread the cables through the eye-
screws. With the firebox placed close to
the fireplace opening feed the two cables
Page 24
Terminal/
Air Duct
14. Feed each bare cable end into the hole
15. Slide each of the tensioning screws all
16. Whilst holding the cable tensioning
17. Roll up the excess cable and tuck it
through the matching eye screws (left
cable through left hand set of eyelets
and the same for right hand cable) and
then back into the holes at the bottom
rear of the firebox (see Figure 32).
Remove the grommet from the gas inlet
slot on the firebox to allow for gas pipe to
come through. Whilst pulling the cables,
push the firebox gently into the opening
(ensuring that the gas pipe emerges
from the rear slot) until the flange of the
firebox abuts the fire surround (or the
wall).
in the brackets on the base of the firebox
and in turn through the hole at the
threaded end of the cable tensioning
screw. (See
Figure 27)
the way onto the cable and through the
hole in the bracket.
screw in the bracket pull the cable taught
and without releasing the tension tighten
the thumb screw firmly. To further tighten
the
cables,
screw
clockwise.
away. Do NOT CUT the excess cable.
the
wing
nuts

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents