Flue Terminal Location - Magiglo TRIBUTE PD-08-002 User, Installation & Servicing Instructions

Table of Contents

Advertisement

3.6.

Flue Terminal Location

The minimum acceptable dimensions from the flue terminal to obstructions and ventilating
openings are shown in Table 3 and Figure 20.
Dimension
A
Directly below an opening, air brick, opening windows, etc.
B
Above an opening, air brick, opening window, etc.
C
Horizontally to an opening, air brick, opening window, etc.
D
Below gutters, soil pipes or drain pipes
E
Below eaves
F
Below balconies or car port roof
G
From a vertical drain pipe or soil pipe
H
From an internal or external corner
I
Above ground, roof or balcony level
J
From a surface facing the terminal
K
From a terminal facing a terminal
From an opening in the car port (e.g. door, window) into the
L
dwelling
M
Vertically from a terminal on the same wall
N
Horizontally from a terminal on the same wall
I
F
L
J
Page 16
Terminal Position
Table 3
D,E
B
C
A
G
I
Figure 20
N
N
H
H
I
Value
mm
300
300
300
300
300
600
300
600
300
600
600
1200
1500
300