Agency Compliance and Standards
The Arizona 250 GT complies to the following Agencies and Standards:
Note: Third Party confirmation of all declared will be obtained.
Safety
Berufsgenossenschaft GS Mark and BG-Prufzert - Mechanical and Electrical Safety
Printing Equipment: EN1010
Machinery Electrical Safety: EN60204 including Annex 1
Machinery Mechanical Safety: EN954-1, EN1050-1
Machinery UV Radiation Safety measured according to: EN12198-1 and
EN12198-2
IT Equipment Electrical Safety: EN60950-1:2001 (with CB Scheme Report)
Note: All applicable compliance certificates are available on our web site: see
http://www.dgs.oce.com/PrinterSupport/Arizona250GT_Customer/
EMC
EMC Directive: CE Marking
EN55022: 1998 Information Technology Equipment. Emmisions Characteristics.
EN55024: 1998 Information Technology Equipment. Immunity Characteristics.
EN 61000-6-3:2001 Emissions: Residential, Commercial and Light-Industrial
Equipment, Generic
EN 61000-6-1:2001 Immunity: Residential, Commercial and Light-Industrial
Equipment, Generic
R&TTE Directive: ETSI EN 301 489-01 V1.5.1, ETSI EN 301 489-03 V1.4.1
USA and Canada: 47 CFR Part 15 & Industry Canada.
Limits for Voltage Fluctuations and Flicker:
This equipment does not meet the requirements for EN61000-3-3:
Apply Clause 6.2.2EN61000-3-11
This equipment is subject to conditional connection:
This equipment may only be connected to mains connections with an impedance at
50Hz of Zsys = 0.268 + j0.168 Ohm or less. In case it is observed that this
equipment causes 'lightflicker' to the environment, contact the supply authority in
order to verify if the mains network has lower impedance than the one specified
above.
Noise Measurement Test Summary
Tested according to EN13023:2003, EN11204, ISO3744:1994(E)/ISO3746:1995(E)
and declared according to ISO4871:1984(E)
Measurements taken at the sample in 5 different locations, Printer in normal
operation with Vacuum Pump, does not exceed 75dB (maximum measured value:
66dB). For all locations, provide noise protection enclosure or remove pump from
location.