POD Deck Air Heater errorr
high.
[POD Deck Lite] Air Heater
E906-
low temperature error When
0002
the heater does not become
Ready although a specified
period of time has passed.
Timeout error
The DC Controller is not
E996-
stopped. The Detailed Code
xxxx
varies according to the state
transition of the software.
94
1. Check connector disconnection/improper
connection. - > Disconnect and then connect the
connector. Target connector: Deck Lite Controller
J03, J05 BoxDriver J52, J54, J58, J59 2. Replace
the Air Heater. 3. Replace the Deck Lite Controller
PCB.
Turn OFF and then ON the main power.