Controller Cooling Fan error
E880-
The failure of the controller cooling fan
0001
(FM12) is detected.
Controller Cooling Fan error
1. Check the connector (J1015). 2.
E880-
Replace the controller cooling fan
0005
(FM12). 3. Replace the main controller
PCB 1 (UN25).
Canon iR Advance 6055 Trouble Error Codes List
Code
Fixing Assembly low temperature error
Temperature of the Fixing Main
E000-
Thermistor (THM1) does not reach 70
0001
degC although 20 seconds have
passed after starting the Fixing Roller
temperature control.
Fixing Assembly low temperature error
Temperature of the Fixing Main
E000-
Thermistor (THM1) does not reach 10
0002
degC although 20 seconds have
passed after starting the Fixing Roller
temperature control.
Fixing Assembly low temperature error
E000-
Turning OFF and then ON the power
0010
without clearing the error.
38
Description
1. Check the connector (J1015). 2.
Replace the controller cooling fan
(FM12). 3. Replace the main controller
PCB 1 (UN25).
Controller Cooling Fan (FM12) is
detected.
Remedy
1. Check the connection of the Fixing
Assembly. (Connection error of the
Drawer, connector disconnection, open
circuit) -> Replace the Heater
Assembly. 2. Check the connection
between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB
(PCB10) (connector disconnection,
open circuit, the caught cable). 3.
Replace the Fixing Power Supply PCB
(PCB10). 4. Replace the Main Driver
PCB (PCB2). 5. Replace the DC
Controller PCB (PCB1).
1. Check the connection of the Fixing
Assembly. (Connection error of the
Drawer, connector disconnection, open
circuit) -> Replace the Heater
Assembly. 2. Check the connection
between the Main Driver PCB (PCB2)
and the Fixing Power Supply PCB
(PCB10) (connector disconnection,
open circuit, the caught cable). 3.
Replace the Fixing Power Supply PCB
(PCB10). 4. Replace the Main Driver
PCB (PCB2). 5. Replace the DC
Controller PCB (PCB1).
Clear the error.