Code
Description
Fixing temperature abnormal rise
The temperature detected by the
E000-
main thermistor does not rise to
0001
the specified value during startup
control.
Fixing unit temperature rise
detection
E001-
The reading of the main thermistor
0000
is 250 deg C or more continuously
for 200 msec.
Fixing unit temperature rise
detection
E001-
The hardware circuit detects
0001
overheating of the main or sub
thermistor for 30 msec.
Fixing unit temperature rise
detection
E001-
The reading of the sub thermistor
0002
is 295 deg C or more continuously
for 200 msec.
Fixing unit temperature insufficient
rise
1. The reading of the main
E002-
thermistor is less than 115 deg C
0000
continuously for 400 msec 2.5 sec
after it has indicated 100 deg C. 2.
The reading of the main thermistor
2
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor
(Film Unit). 4. Replace the Fixing Main
Unit. 5. Replace the DC Controller PCB
(UN2).
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor
(Film Unit). 4. Replace the Fixing Main
Unit. 5. Replace the DC Controller PCB
(UN2).
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Replace the DC Controller
PCB (UN2).
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor
(Film Unit). 4. Replace the Fixing Main
Unit. 5. Replace the DC Controller PCB
(UN2).
1. Go through the following to clear the
error: COPIER> FUNCTION> CLEAR>
ERR; and then turn OFF and then ON
the power. 2. Check connection of the
Connectors (Thermistor Connector:
J2063/J2510/J214, AC Connector: J105).
3. Replace the Fixing Main Thermistor
Remedy

Advertisement

loading