Cassette 4 Lifter Motor error
E041-
Overcurrent of the Cassette 4 Lifter
0004
Motor was detected.
Error in Reverse Upper Flapper
Solenoid connection detection
E053-
Connection of the Reverse Upper
0001
Flapper Solenoid (SL5) cannot be
detected 5 times with 20 msec time
interval.
Primary Charging Shutter HP open
error
E060-
The Primary Charging Shutter Sensor
0001
(PS94) detects that the shutter is
opened although it is moved to the
close position.
46
1. Check for error around the Lifter of
the Cassette 4. 2. Check for hindrance
to smooth movement of the Cassette
Base Plate of the Cassette 4.
1. Check the connection of the Reverse
Upper Flapper Solenoid (SL5). Solenoid
side: J2115, Duplex Driver PCB side:
J340 2. Replace the Reverse Upper
Flapper Solenoid (SL5). 3. Replace the
Duplex Driver PCB (PCB4). 4. Replace
the DC Controller PCB (PCB1).
1. Check the position of the Primary
Charging Shutter and the Cleaning Pad.
1-A. In the case that the Primary
Charging Shutter and the Cleaning Pad
fail to operate (stopped at HP at front
side) 1-A-1. Check the connection of the
Primary Charging Wire Cleaning Motor
(M6). Motor side: J3017, J3060 (iR-ADV
8xxx)/J3160 (iRADV 6xxx) (relay), PCB
side: J3177 (relay), J107 (Main Driver
PCB (PCB2)) 1-A-2. Replace the
Primary Charging Wire Cleaning Motor
(M6). 1-B. In the case that the Primary
Charging Shutter and the Cleaning Pad
are stopped at rear side (close
operation position) 1-B-1. Check the
connection of the Primary Charging
Shutter Sensor (PS94). Sensor side:
J2029, J3089 (relay), PCB side: J3088
(relay), J114 (Main Driver PCB (PCB2))
1-B-2. Replace the Primary Charging
Shutter Sensor (PS94). 1-C. In the case
that the Primary Charging Shutter and
the Cleaning Pad are stopped along the
way 1-C-1. Check the loosening of
screw on the Slider Pin and abrasion of
the pin. Tighten the screw or replace the
Slider Pin. 1-C-2. Replace the Primary
Charging Assembly. 1-D. In the case
that the Primary Charging Shutter stops
at front side and the Cleaning Pad
moves to rear side 1-D-1. Check if the
Shutter Mounting Plate is deformed. If
so, replace the Shutter Unit. 1-D-2.