Canon imageRUNNER ADVANCE 4045 Trouble Error Codes List page 58

Hide thumbs Also See for imageRUNNER ADVANCE 4045:

Advertisement

Power supply (24V) error
E227-
24V port is OFF when the
0001
power is turned ON.B
Power supply (24V) error
E227-
24V port is OFF when a job
0002
is started.
Power supply (24V) error
E227-
24V port is OFF when a job
0003
is ended.
Power supply (24V) error
E227-
24V port is OFF when
0004
loading.
Power supply (24V) error
E227-
24V port is OFF when the
0101
power of DADF is turned
ON.
Power supply (24V) error
E227-
24V port is OFF when a job
0102
is started in the DADF.
Power supply (24V) error
E227-
24V port is OFF when a job
0103
is ended in the DADF.
Communication error
between Main Controller and
DC Controller
E240-
Communication error occurs
0000
between the CPU of the
Main Controller PCB and the
DC Controller PCB (PCB1).
3 minutes passed with
pickup request waiting status
E240-
It was detected that 3
0001
minutes passed with pickup
request waiting status.
E240- 3 minutes passed with image 1. Check the connection of the Connector. 2.
58
Driver PCB (PCB1).
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply.
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply.
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply
1. Connector disconnection/open circuit of the
Reader Power Supply. 2. Failure of power supply.
1. Connection error between the DADF Driver
PCB (PCB1) and the Reader Controller PCB
(PCB1). 2. Connector disconnection/open circuit
of the Reader Power Supply. 3. Failure of power
supply.
1. Connection error between the DADF Driver
PCB (PCB1) and the Reader Controller PCB
(PCB1). 2. Connector disconnection/open circuit
of the Reader Power Supply. 3. Failure of power
supply.
1. Connection error between the DADF Driver
PCB (PCB1) and the Reader Controller PCB
(PCB1). 2. Connector disconnection/open circuit
of the Reader Power Supply. 3. Failure of power
supply.
1. Check the connection of the Main Controller
PCB and the DC Controller PCB (PCB1). Main
Controller side: J712, DC Controller side: J442 2.
Replace the DC Controller PCB (PCB1). 3.
Replace the Main Controller PCB.
1. Check the connection of the Connector. 2.
Check the connection of the Sub PCB in the Main
Controller PCB 1 Box. 3. Check the connections
of the DC Controller PCB and the Main Controller
PCB 1. Replace the PCB(s) if necessary.

Advertisement