Download Print this page

Canon imageRUNNER ADVANCE 4045 Trouble Error Codes List page 73

Hide thumbs Also See for imageRUNNER ADVANCE 4045:

Advertisement

Punch home position error
(External 2 Hole Puncher)
E590-
The Puncher does not detect the
8001
Punch Home Position Sensor
when the Puncher Motor has
been driven for 200 msec.
Punch home position error
(External 2 Hole Puncher)
After the Motor has been
E590-
stopped at time of Punch Motor
8002
initialization, the Puncher does
not detect Punch Home Position
Sensor.
Scrap full detection error
(External 2 Hole Puncher)
The voltage of the light received
E591-
is 3.0 V or less even when the
8001
light emitting duty of the Scrap
Full Detector Sensor has been
increased to 66% or more.
Scrap full detection error
(External 2 Hole Puncher)
The voltage of the light received
E591-
is 2.0 V or more even when the
8002
light emitting duty of the Scrap
Full Detector Sensor has been
decreased to 0%.
Trailing Edge Sensor error
(External 2 Hole Puncher)
The voltage of the light received
E592-
is 2.5 V or less even when the
8001
light emitting duty of the Trailing
Edge Sensor (LED5, PTR5) has
been increased to 66% or more.
Trailing Edge Sensor error
E592-
(External 2 Hole Puncher)
8002
The voltage of the light received
73
(CL101), ang Stack Ejection Lower Roller
Clutch (CL102) is faulty. 5. The Finisher
Controller PCB is faulty.
1. The Punch Home Position Sensor
(PI63) and Punch Motor Clock Sensor
(PI62) is faulty. 2. The wiring between the
Punch Controller PCB and Sensor is
faulty. 3. The punch mechanism is faulty.
4. The punch motor (M61) is faulty. 5. The
Punch Controller PCB is faulty. 6. The
Finisher Controller PCB is faulty.
1. The Punch Home Position Sensor
(PI63) and Punch Motor Clock Sensor
(PI62) is faulty. 2. The wiring between the
Punch Controller PCB and Sensor is
faulty. 3. The punch mechanism is faulty.
4. The punch motor (M61) is faulty. 5. The
Punch Controller PCB is faulty. 6. The
Finisher Controller PCB is faulty.
1. The wiring between the Scrap Full
Detector PCB and Punch Controller PCB
is faulty. 2. The Scrap Full Detector PCB is
faulty. 3. The Punch Controller PCB is
faulty. 4. The Finisher Controller PCB is
faulty.
1. The Scrap Full Detector PCB is faulty. 2.
The Punch Controller PCB is faulty. 3. The
Finisher Controller PCB is faulty.
1. The wiring between the LED
PCB/Photosensor PCB and Punch
Controller PCB is faulty. 2. The LED PCB
and Photosensor PCB is faulty. 3. The
Punch Controller PCB is faulty. 4. The
Finisher Controller PCB is faulty.
1. The LED PCB and Photosensor PCB is
faulty. 2. The Punch Controller PCB is
faulty. 3. The Finisher Controller PCB is

Advertisement