(S26) connection detection signal
is absent for 100 msec 10 times in
sequence. * Error occurs after the
delivery if a paper in passage
exists.
Code
Description
Failure of the Bottle Motor (M17)
When the disconnection status of
the bottle motor (M17) is detected
15 times or more continuously
with the 100ms cycle during the
E025-
intermittent rotation When the
0001
disconnection status of the bottle
motor (M17) is detected 75 times
continuously with the 100ms
cycle during the continuous
rotation * Error occurs after
delivering the remaining paper.
Failure of NE Controller Counter
E032-
Detection of open circuit of count
0001
pulse signal.
Failure of the Polygon Motor
(M11)
The Polygon Motor (M11) speed
lock signal does not indicate a
E110-
locked state a specific period of
0001
time after the Polygon Motor
(M11) has been started. * The
same condition is detected after
the error retry is performed.
Failure of the Polygon Motor
(M11)
The speed lock signal indicates a
deviation 10 times in sequence at
E110-
intervals of 100 msec after the
0002
signal has indicated a locked
state. * The same condition is
detected after the error retry is
performed.
Failure of the Polygon Motor
E110-
(M11)
0003
The Polygon Motor (M11) speed
5
1. Check connection of the Connector
(J2216/J2503/J207). 2. Replace the Bottle
Motor (M17). 3. Replace the DC Controller
PCB (UN2).
Disconnection of cable.
1. Check connection of the Connector
(J1/J7/J10/J21/J208/ J8142/J8143). 2.
Replace the Laser Scanner Unit. 3.
Replace the DC Controller PCB (UN2).
1. Check connection of the Connector
(J1/J7/J10/J21/J208/ J8142/J8143). 2.
Replace the Laser Scanner Unit. 3.
Replace the DC Controller PCB (UN2).
1. Check connection of the Connector
(J1/J7/J10/J21/J208/ J8142/J8143). 2.
Replace the Laser Scanner Unit. 3.
Remedy