8.3

Changing status monitor function

Changing the display format while power is on
The item displayed in the standard monitor mode (*1 on the left side of table on page H-2), for example, operation
frequency which is displayed by default in this way: "=" when power is on or "" when power is off, can be
changed to any item shown on page H-7. This new format, however, will not display an assigned prefix such as 
or .
・ Standard monitor mode ⇒ Standard monitor display selection ()
Title


Specify how to output the monitored values that are assigned to status monitors 1 through 8.
If  is set to , the monitored values selected with  (standard monitor display selection parameter) are
displayed one after another.
For peak hold values and minimum hold values, the minimum values in each operation mode are displayed. When
the motor is at a standstill, the values monitored last are held as they were until the motor is started the next time.
The maximum and minimum values monitored after power is turned on or after the reset with the EASY key are
always displayed no matter whether the motor is in operation or at a standstill.
Changing contents of status monitor indication
Regarding contents of status monitor indications appearing in the left column of the table on page H-2, those
marked with *2 to *9 can be changed for others. Select a desirable monitor function from among optional monitor
functions appearing on page H-7.
*2 Frequency command
*3 Output current
8
*4 Input voltage
*5 Output voltage
*6 Torque
*7 Regenerative braking resistance overload factor
*8 Inverter overload factor
*9 Motor overload factor
Title








*If  to  are set at "" (Output frequency) the operation frequency is not held in trip status.
Function
:Real time
Standard monitor hold
:Peak hold
function
:Minimum hold
~
Standard monitor
⇒ Refer to page H-7.
display selection
Function
Status monitor 1 display selection
Status monitor 2 display selection
Status monitor 3 display selection
Status monitor 4 display selection
Status monitor 5 display selection
Status monitor 6 display selection
Status monitor 7 display selection
Status monitor 8 display selection
Adjustment range
⇒ Changeable by status monitor 1 display selection ().
⇒ Changeable by status monitor 2 display selection ().
⇒ Changeable by status monitor 3 display selection ().
⇒ Changeable by status monitor 4 display selection ().
⇒ Changeable by status monitor 5 display selection ().
⇒ Changeable by status monitor 6 display selection ().
⇒ Changeable by status monitor 7 display selection ().
⇒ Changeable by status monitor 8 display selection ().
Adjustment range
~ ⇒ Refer to page H-7.
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
H-6
E6581528
Default setting


Default setting







