6.36.8 Torque-related parameters for panel operation
 : Operation panel tension torque bias
 : Operation panel load sharing gain
These parameters are used to specify the torque bias and how to share the load.
⇒ For details, refer to Instruction Manual (E6581331) specified in Section 6.42.
6.37

Tracing functions

 : Trace selection
 : Trace cycle
• Function
These parameters are used to memorize and read out the data collected at the time of tripping or triggering.
Up to 4 kinds of data can be selected from 64 kinds of data, and the data collected at 100 consecutive
points can be stored in memory as trace data.
Here is the time at which trace data is acquired.
• Tripping: Data collected before the occurrence
• Triggering: Data collected after triggering
Note: To read data on a PC.
Title

Trace selection

Trace cycle
* 1

Trace data 1

Trace data 2

Trace data 3

Trace data 4
 : Trace data 1
 : Trace data 2
 : Trace data 3
 : Trace data 4
Function
F-73
Adjustment range
:Deselect
:At tripping
:At triggering
:4ms
:20ms
:100ms
:1s
:10s
~
~
~
~
E6581528