Toshiba TOSVERT VF-AS1 Instruction Manual page 197

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

Trace data communication number
Communication
No.
E000
E100
E199
E200
E299
E300
E399
E400
E499
Ex.) When operation frequency data is acquired through a communication device
Data acquired () h=8000 ⇒ 8000×0.01Hz=80.0Hz
Relationship between pointer and data
The table below shows the relationship between pointer (E000 set value) and trace data (1 to 4).
Pointer (E000 set value)
Trace data 1 ( E100 ~ E199 )
Trace data 2 ( E200 ~ E299 )
6
Trace data 3 ( E300 ~ E399 )
Trace data 4 ( E400 ~ E499 )
<Example of setting> If E000 is set to :
Trace data 1
Trace data 2
Trace data 3
Trace data 4
Note 1: Use the parameters  through to specify the types of trace data (1 to 4).
Note 2: Communication numbers E000 is automatically incremented by the inverter when data is traced
6.38
Integral output power
 : Integral output power retention selection
 : Integral output power display unit selection
• Function
At the main power off ,it is selectable whether retention of integral output power values or not.
And also, the display unit is selectable.
Title


Function
Trace data 1~4 pointer
Data 1 of trace data 1
Data 2~99 of trace data 1
Data 100 of trace data 1
Data 1 of trace data 2
Data 2~99 of trace data 2
Data 100 of trace data 2
Data 1 of trace data 3
Data 2~99 of trace data 3
Data 100 of trace data 3
Data 1 of trace data 4
Data 2~99 of trace data 4
Data 100 of trace data 4
(Earliest data)
E102
~
E199, E100, E101
E202
~
E299, E200, E201
E302
~
E399, E300, E301
E402
~
E499, E400, E401
continuously.
* In ordinary cases, these parameters do not need to be rewritten.
Function
Integral output power retention selection
Integral output power display unit selection
Minimum setting
Setting/readout range
/readout unit
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1
~
1 / 1



E100
E101
E102
E200
E201
E202
E300
E301
E302
E400
E401
E402
(Latest data)
Adjustment range
: Disabled
: Enabled
: 1 = 1 kWh
: 0.1 = 1 kWh
: 0.01 = 1 kWh
: 0.001 = 1 kWh
: 0.0001 = 1 kWh
F-76
E6581528
Default setting















~
~
E198
E199
~
E298
E299
~
E398
E399
~
E498
E499
Default setting

Accoding to
model
⇒ Refer to
page K-47.