3) Control circuit terminal block
The control circuit terminal block is common to all equipment.
(VFAS1- ***** -WN,HN)
⇒ For details on all terminal functions, refer to Section 2.3.2.

1.4.2 Detaching the cover

Main circuit terminal cover
To wire the main circuit terminal for models VFAS1-5015PM to 5075PM, remove the main circuit terminal cover in
line with the steps given below.
(A)
Open the main circuit terminal cover.
* To open the cover, lift it with your finger
placed at the part
the cover.
PWR-P24/PLC Shorting bar
Control circuit terminal block screw size: M3
on the right side of
A-9
Serial 4-wire RS485
connector
(B)
90°
(1)
(2)
Main circuit terminal
Remove the main circuit terminal cover.
* Turn the screw securing the cover
counterclockwise by 90° to release the
lock (do not turn the screw by more than
90°. Or the screw might be broken.), and
then hold the cover by both ends and pull
the cover up, slightly bending it inward.