Toshiba TOSVERT VF-AS1 Instruction Manual page 118

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

690V-50Hz default setting(=)
Setting  tocauses default value is to be set for 690V-50Hz.
When  to be set after setting default value is to be set for 690V-50Hz (same value as )
Setting  tocauses all the following parameters to be changed from factory shipment (setting)
• Base frequency 1 
• Base frequency voltage 1 
. • Upper limit frequency 
• VI/II input point 2 frequency 
• RR/S4 input point 2 frequency 
• Base frequency 2 
• Base frequency voltage 2 
• Base frequency 3 
• Base frequency voltage 2 
• Base frequency 4 
• Base frequency voltage 4 
• RX input point 2 frequency 
• AI1 input point 2 frequency 
• AI2 input point 2 frequency 
: 50Hz
• RP/high-speed pulse input point 2 frequency 
: 690V
• Automatic light-load high-speed operation frequency  : 50Hz
: 50Hz
• Commercial power/inverter switching frequency 
: 50Hz
• PID deviation upper limit 
: 50Hz
• PID deviation lower limit  : 50Hz
: 50Hz
• Process upper limit 
: 690V
• PID output upper limit 
: 50Hz
• Forward speed limit input level 
: 690V
• Reverse speed limit input level 
: 50Hz
• Undervoltage detection level 
: 690V
• Overvoltage limit operation level 
: 50Hz
• Regenerative power ride-through control level : 75%
: 50Hz
• Point 2 frequency 
: 50Hz
E-45
E6581528
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 50Hz
: 59%
:113%
: 50Hz
5