Fault Code Register - SDMO RENTAL POWER R550C2 User And Maintenance Manual

Generating sets
Table of Contents

Advertisement

Fault Code Register

No fault (Code 1.1)
Cause
There are no active faults.
Preheating Relay (Code 5.4, PID 45/SPN 626)
Cause
Short circuit to positive (+) or
earth (ground) (–).
Open circuit.
Fuel Pressure Sensor (Code 3.6, PID/SPN 94)
Cause
Short circuit to positive (+) or
earth (ground) (–).
Open circuit.
Fuel Pressure (Code 3.8, PID/SPN 94)
Cause
Low supply pressure
Water in Fuel (Code 2.1, PID/SPN 97)
Cause
Water in fuel
Indicator for Water in Fuel (Code 2.9, PID/SPN 97)
Cause
Short circuit
Open circuit
Fault in indicator
Oil Level (Code 5.7, PID/SPN 98)
Cause
Oil level to low
36
Reaction
Reaction
Preheating can not be acti-
vated.
Preheating is constantly con-
nected.
Reaction
None
Reaction
None
Reaction
None
Reaction
None
Reaction
None
164/298
Remedy
Remedy
Check that the relay input
cable is not damaged.
Check relay function.
Remedy
Check that the fuel pressure
sensor connector is correctly
installed.
Check that the fuel pressure
sensor cable is not damaged.
Check that the fuel pressure
sensor is correctly installed.
Check fuel pressure sensor
function.
Remedy
Check if it is possible to build
up pressure with the hand
pump
Check the fuel filter
Check the fuel pre-filter
Remedy
Empty the primary fuel filter
Remedy
Check the indicator cables for
breaks and short circuits
Check indicator function.
Change indicator as neces-
sary
Remedy
Check the oil level
7748681 12-2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents