8. Storing the generating set

Generating sets which are to remain unused for a long period of time must undergo certain procedures, in order to keep them in good condition.
Check that the storage area is not dusty or humid. Clean the exterior of the generating set and apply rustproofing product.
Close the fuel tap (O position), remove the sediment bowl and drain it.
Open the fuel tap (I position) and drain the petrol from the tank into a suitable container.
Refit the sediment bowl and tighten fully.
Drain the carburettor by loosening the drain screw. Collect the petrol in a suitable container.
Change the engine oil.
Remove the spark plug and pour about 15 ml of oil into the cylinder, then refit the spark plug.
Leave the engine to run for a few moments to distribute the oil in the cylinder.
Clean the generating set and cover the engine again to protect it from dust.
Store the generating set in a clean, dry place.

9. Fault finding

The generating set is being charged during start-up
Fuel level too low
The motor will not
The fuel tap is closed
start
Fuel supply blocked or leaking
Blocked air filter
Control in OFF position or "О"
The motor cuts out
Blocked ventilation inlets
Possible overload
Circuit breaker tripped out
Faulty circuit breaker
No electric current
Faulty plug sockets
Faulty appliance supply lead
Faulty alternator
Circuit breaker trips
Generating set overload
out
Faulty equipment or lead
10. Specifications
Model
Engine type
Output (Watts)
Direct current
Alternating current
Socket type
Circuit breaker
Oil guard
Battery
Acoustic pressure at 1 m
Weight in kg (without fuel)
Dimensions l x w x h in cm
Recommended oil
Oil sump capacity in L
Recommended fuel
Fuel tank capacity in litres
Spark plug
●: standard
○: optional
Probable causes
Probable causes
Probable causes
Probable causes
SH6000-2 UK
Honda GX 390
6000 max
X
115V-52A
230-26A
1 x 16A
1 x 32A
CEE 17 –
CEE 17 -
2P+T
2P+T
X
84dB(A)
81
77.5x57x59
SAE10W30
1.1
Unleaded petrol
26
NGK: BPR6ES or DENSO: W20 EPR-U
X: impossible
Take it off charge
Fill up with fuel
Open the fuel tap
Have the system repaired
Clean the air filter
Switch the control to ON or "I"
Clean the air inlet and outlet guards
Check the load
Reset the circuit breaker
Have it checked, repaired or replaced
Have it checked, repaired or replaced
Change the leads
Have it checked, repaired or replaced
Reduce the load
Have it checked, repaired or replaced
115V-52A
230-26A
1 x 16A
1 x 32A
CEE 17 –
CEE 17 -
2P+T
2P+T
Remedial action
Remedial action
Remedial action
Remedial action
SH6000E-2 UK
Honda GX 390
6000 max
X
115V-52A
230-26A
1 x 16A
1 x 32A
CEE 17 –
CEE 17 -
2P+T
2P+T
X
84dB(A)
87
87x56x56
SAE10W30
1.1
Unleaded petrol
26
NGK: BPR6ES or DENSO: W20 EPR-U
115V-52A
230-26A
1 x 16A
1 x 32A
CEE 17 –
CEE 17 -
2P+T
2P+T