SPN
CID
SID
PID
608
250
608
608
611
620
262
232
626
45
627
628
240
629
254
630
253
632
PPID
FMI
9
132
98
3
4
3
4
3
4
5
1
4
18
2
8
11
12
13
19
2
5
Description
Gear selection invalid
Data link faulty J1587 Start/Stop
redundancy / J1939 communication
bus
Redundancy of the accelerator
Redundancy of the Stop/start
information
Injector wiring status
Injector wiring shorted to power source
Injector wiring shorted to ground
5 Volt sensor power supply
Sensor power supply open/short to B+
Sensor power supply short to ground
Start enable device (intake heater and
ether)
Start enable device output short to B+
Start enable device output short to
ground
Start enable device output open circuit
Power supply
Injector supply voltage problem
ECU unswitched power missing
Battery voltage below the operating
voltage
Memory fault in EMS2
ECU status/controller error
RAM cell test failure
CPU watchdog reset test failure
Main and fuelling ASIC test fail
RAM address test failure
Watchdog trip failure
ECU to injection pump communication
error
Data set memory EEPROM
Injection status
Fuel shutoff error
Fuel shutoff non-functional
288/298
Comment
Not possible with Genset
application
FMI not informed by
VOLVO
Not used, the control panel
is in charge of managing the
start enable device
For 6125HF070 only
For 6068HF275 VP44 only
For John DEERE Tiers III
CIU module status
Possible only with
6068HF475 VP44