SDMO RENTAL POWER R550C2 User And Maintenance Manual page 293

Generating sets
Table of Contents

Advertisement

SPN
CID
SID
PID
654
4
4
654
655
5
5
655
656
6
6
656
676
39
PPID
FMI
0
1
2
3
4
5
6
7
11
0
1
2
3
4
5
6
7
11
0
1
2
3
4
5
6
7
11
3
5
Description
Cylinder #4 injector status
Injector outside the specifications
Injector outside the specifications
Short circuit high side to B+
Short circuit high side to low side or low
side to B+
Short circuit high or low side to ground
Cylinder #4 circuit open
Cylinder #4 circuit shorted
Cylinder #4 balancing error/mechanical
failure
Cylinder #4 unknown error/mechanical
failure
Cylinder #5 injector status
Injector outside the specifications
Injector outside the specifications
Short circuit high side to B+
Short circuit high side to low side or low
side to B+
Short circuit high or low side to ground
Cylinder #5 circuit open
Cylinder #5 circuit shorted
Cylinder #5 balancing error/mechanical
failure
Cylinder #5 unknown error/mechanical
failure
Cylinder #6 injector status
Injector outside the specifications
Injector outside the specifications
Short circuit high side to B+
Short circuit high side to low side or low
side to B+
Short circuit high or low side to ground
Cylinder #6 circuit open
Cylinder #6 circuit shorted
Cylinder #6 balancing error/mechanical
failure
Cylinder #6 unknown error/mechanical
failure
Glow plug relay status
Glow plug relay voltage high
Glow plug relay voltage low
291/298
Comment
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required
Recalibration of the injectors
required

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents