SDMO RENTAL POWER R550C2 User And Maintenance Manual page 178

Generating sets
Table of Contents

Advertisement

Fault Code Register
Fan actuator (SID 33/SPN 975)
Cause
Short circuit to positive (+) or
negative (-)
Open circuit
Fan actuator damaged
mechanically
Calibration memory EEPROM (SID 232, SPN 628)
Possible reason
Control unit
CAN1 J1939 time out (PSID 201, SPN 2029)
Possible reason
Faulty harness
Faulty sensor
Faulty fuse
48
TAD1650VE, TWD1643GE
Reaction
Warning lamp lights up
EATS
Fault codes for the EATS system is in the installation
manual for this system.
Reaction
None
Reaction
None. Fault only visible in
Vodia.
176/298
Remedy
Check that the fan actuator is
properly mounted
Check that the wiring to the
fan actuator is not damaged
Check that the fan actuator is
correctly mounted
Check the fan actuator
Action
Check cables and connec-
tions
Action
Check wiring
Check the sensor
Check the fuse
7748681 12-2011