Fault Code Register
Fan actuator (SID 33/SPN 975)
Cause
•
Short circuit to positive (+) or
negative (-)
•
Open circuit
•
Fan actuator damaged
mechanically
Calibration memory EEPROM (SID 232, SPN 628)
Possible reason
•
Control unit
CAN1 J1939 time out (PSID 201, SPN 2029)
Possible reason
•
Faulty harness
•
Faulty sensor
•
Faulty fuse
48
TAD1650VE, TWD1643GE
Reaction
•
Warning lamp lights up
EATS
Fault codes for the EATS system is in the installation
manual for this system.
Reaction
•
None
Reaction
•
None. Fault only visible in
Vodia.
176/298
Remedy
•
Check that the fan actuator is
properly mounted
•
Check that the wiring to the
fan actuator is not damaged
•
Check that the fan actuator is
correctly mounted
•
Check the fan actuator
Action
•
Check cables and connec-
tions
Action
•
Check wiring
•
Check the sensor
•
Check the fuse
7748681 12-2011