Maintenance
P0002089
M A X
M I N
p0005248
TAD1650VE
62
Lubrication System
Oil change intervalls may vary according to the lubri-
cation oil grade and fuel sulfur content. Refer to Tech-
nical data, Lubrication system.
NOTICE! Oil change intervals must never exceed a
period of 12 months.
If longer oil change intervals than those given in Tech-
nical data are required, the condition of the oil must be
checked by the oil manufacturer via regular oil tests.
Oil level, checking and topping up
The oil level must be inside the marked area on the
dipstick and must be checked daily before the first
start.
Top up with oil via the filler opening, please refer to
Maintenance page 52.
The oil level can be read both when the engine is
stationary (the STOP side of the dipstick) and with
the engine running (the OPERATING side of the
dipstick).
Do not fill up above the maximum oil level. Only use
a recommended grade of oil, please refer to Tech-
nical Data page 82
The oil level sensor only measures the oil level at
the time when the ignition is turned on. In other
words, not continually during operation.
TAD1650VE
The oil level must be inside the marked area on the
dipstick and must be checked daily before the first
start.
Top up with oil via the filler opening, located on the side
of the engine. Check that the correct level has been
achieved. If the engine is stationary, wait for a few
minutes to allow the oil to run down into the oil pan.
IMPORTANT!
Do not fill up above the maximum oil level. Only use a
recommended grade of oil, please refer to Technical
Data page 82.
190/298
7748681 12-2011