VJ-1204 OPERATION MANUAL
9. Set up Micro Adjustment Change.
a. Press the [+] key or [–] key to select "PF5:Micro Change".
b. Press the [Enter] key on the operation panel.
•
"Micro: 0pulse" is displayed on the operation panel.
c. Press the [+] key or [–] key and enter the micro adjustment value according to the printing result
in step 7.
d. Press the [Enter] key on the operation panel.
•
The micro adjustment value is saved.
•
"PF5:Micro Change" is displayed on the operation panel.
10. Press the [Cancel] key on the operation panel several times.
•
The operation panel returns to Normal.
•
The adjustment of media feed compensation value is complete.
4-13
4 Handling the printer