IBM TotalStorage DS300 Best Practices Manual page 360

Hide thumbs Also See for TotalStorage DS300:
Table of Contents

Advertisement

22.Select Port 0 of the first HBA of host SEINE. Select the register card Target
Settings. In the target list click the green plus button to add a target portal IP.
Figure 7-183 SANsurfer — Target settings
23.Enter the IP address of controller A's first iSCSI interface 192.168.1.7.
Figure 7-184 SANsurfer — iSCSI Target IP address
24.The target list contains now an not yet saved entry for the iSCSI target
192.168.1.7. When no iSCSI qualified name is specified than this entry is
used to perform a discovery of available LUNs on this target. A list of all LUNs
is requested by issuing the sendtargets command. This automatic discovery
is only performed when the Auto-discover checkbox is checked and the
configuration is saved. Click Save Settings.
342