DS300-1[A]# interface manage eth3[B] ip 192.168.1.126
Please wait.
Interface values are now:
Broadcast address: 192.168.1.255
DS300-1[A]# interface manage eth3[B] netmask 255.255.255.192
Please wait.
Interface values are now:
Broadcast address: 192.168.1.255
DS300-1[A]# interface manage eth3[B] broadcast 192.168.1.127
Please wait.
Interface values are now:
Broadcast address: 192.168.1.127
DS300-1[A]#
Figure 4-12 Configure ETH3[B]
The network setup is now completed. The TotalStorage DS300 can now be
managed by the IBM ServeRAID Manager. The agent must now be added to the
Management Station. See section "Configure and run IBM ServeRAID Manager"
on page 97.
To change the network settings for the management ports, use ETH0 on single
controller models and ETH0[A] and ETH0[B] for dual controller models with the
commands shown above.
Note: Changes of the network configuration of a TotalStorage DS300 or
DS400 need to be saved to be available after a reboot. Run the command
save in the CLI to save the configuration. This is required on only one
controller.
86
IBM TotalStorage DS300 and DS400 Best Practices Guide
IP address: 192.168.1.126
Netmask: 255.255.255.0
IP address: 192.168.1.126
Netmask: 255.255.255.192
IP address: 192.168.1.126
Netmask: 255.255.255.192