ENSONIQ DP/4 Musician's Manual page 158

Hide thumbs Also See for DP/4:
Table of Contents

Advertisement

142
Section 6 -
System-MIDI Mode
nr
UO
06 -
Unit Bypass
Unit
MIDI
1=1
Bypass=
Pit.ch Bend
Range:
various
This parameter allows you to choose the controller source which will function as a bypass switch
for the
unit.
The available bypass controller sources are:
MIDI Pitch Bend
MIDI Note Number
MIDI Note Velocity
MIDI Aftertouch
DP / 4 Analog CV In
DP /4 Footswitch 1
DP /4 Ftsw1 Toggle
DP / 4 Footswitch 2
DP /4 Ftsw2 Toggle
MIDI Control #000 to #127
Turned Off
The same controller source can be used to modulate and bypass an effect. However, to avoid
unexpected side effects, the modulation and bypass functions should usually be assigned to
different controllers.
Note that MIDI Controllers used for bypass are only received on the DP / 4's Controller channel.
This is:
For:
parameter 06
Unit A
parameter 13
UnitB
parameter 20
UnitC
parameter 27
UnitD
parameter 34
Config