94
Section 4 - Algorithms
06
-
Left/Right
LFO
Range:
Out-at-Phase or In-Phase
When in phase, the left and right choruses
will
modulate their detunes
together.
When out-of-
phase, the detune on the left channel will go up while the detune on the right
will
go
down.
07 -
Chorus Left Delay Time
Range:
0 to 1500 ms
This parameter controls the time delay for the left channel regen delay, and has nothing to do
with the chorus effect.
08 - Chorus Right Delay Time
Range: 0 to 1500 ms
This parameter controls the time delay for the right channel regen delay, and has nothing to do
with the chorus effect.
09 - Chorus Delay Regen
Range:
-99 to +99
This parameter controls the amount of regen (regeneration) applied to the delay time taps. The
sign of the value determines the polarity of the regen.
10 -
Chorus Left Echo Time
Range:
0 to 1500 ms
This parameter controls the chorus echo time for the left side. Higher settings yield a deeper
echo. There are two discrete echoes, one to the left and one to the right.
11
-
Chorus Right Echo Time
Range: 0 to 1500 ms
Controls the chorus echo time for the right side. Higher settings yield a deeper echo.
12
-
Chorus Echo Level
Range:
00 to 99
This parameter controls the volume of the discrete echo for both the left and right sides. Higher
values offer louder echo, while a value of 00 will eliminate the echo. For sustained sounds, mid
echo levels yield a "poor man's reverb."
13- Bass Fc
Range:
0 to 1000 Hz
This parameter sets the cutoff frequency of the lower frequency band shelving filter.
14
-
Bass EQ Gain
Range:
-48 to +24 dB
This parameter sets the amount of boost or cut applied to the low shelving filter.
15 - Treble Fc
Range:
01 KHz to 16KHz
This parameter sets the cutoff frequency of the high shelving filter.
16 - Treble EQ Gain
Range:
-48 to +24 dB
This parameter sets the amount of boost or cut applied to the high shelving filter.
17 - EQ Input Level Trim
Range:
-24 to +00 dB
This parameter allows you to adjust the input volume of the EQs to eliminate the possibility of
clipping boosted signals.
18 -
Mod1 Source
19 - Mod1 Destination
20 -
Mod1 Param Range Min
21 -
Mod1 Param Range Max
22 -
Mod2 Source
23 -
Mod2 Destination
24 -
Mod2 Param Range Min
25 -
Mod2 Param Range Max
See the descriptions under the Algorithm Modulators, found in the beginning of this section.