Download Print this page

GRAPHTEC CE5000-40CRP Service Manual: Explanation Of The Values Of The Main Board Settings

Ce5000 series.
Hide thumbs

Advertisement

7.3 Explanation of the Values of the Main Board Settings

(Default factory settings)
The default factory settings are recorded on the left side plate shown below.
The contents of an example record are shown below.
25
47
X= 0
X= 80 X= -
Y= 4
Y= 50 Y= -
Explanation of the values
10 g
40g
Distance adjustment values
X
Y
You can input the same values when you have replaced the main board without making any adjustments.
If you have changed any values by making adjustments, record those values for the next maintenance check.
CE5000-UM-251-9370
100
228
346
Pen force values
120 g
300 g
Gain adjustment values Auto registration mark position adjustment values
X
Y
7. ELECTRICAL ADJUSTMENTS
The default factory settings
are recorded here.
450 g
X (when the option is installed)
Y (when the option is installed)
7-2

Advertisement

This manual also for:

Ce5000-120, Ce5000-60, Ce5000-120ap

Comments to this Manuals

Symbols: 0
Latest comments:
  • bentayeb Aug 19, 2017 08:49:
    mon ploteur afiche une erreure y position alarm