Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changes the temperature of the actuator and causes artificially lower readings. When this happens the
actual pen force may be higher than the specification. This is especially true for the upper pen force
adjustment.
(13) Press the NEXT key to complete this adjustment.
Specification of the actual pen force
Specified pen force
10g
40g
120g
300g
450g
CE5000-UM-251-9370
Actual force range
8 to 12g
36 to 44g
110 to 130g
280 to 320g
430 to 470g