How To Replace The Y-Motor - GRAPHTEC CE5000-40CRP Service Manual

Ce5000 series
Hide thumbs Also See for CE5000-40CRP:
Table of Contents

Advertisement

6. DISASSEMBLY AND REASSEMBLY

6.2.11 How to Replace the Y-motor

How to detach the Y-motor
(1) Detach the right side cover (see Subsection 6.1.1).
(2) Detach the front guide (see Subsection 6.1.5 or 6.1.6).
(3) Disconnect the Y-motor cables from connector J8 and J11 on the main board.
(4) Loosen the two M3L4WP set screws to detach the Y-motor pulley.
M3L4WP set screw
Y-motor drive belt
M3L6 binding head screw
Y-motor
Y-motor pulley
(5) Remove the three M3L6 binding head screws holding the Y-motor.
(6) Detach the Y-motor pulley, then detach the Y-motor.
(7) Detach the pulley flange and the spacer from the Y-motor.
Y-motor
Spacer
Pulley flange
CE5000-UM-251-9370