GRAPHTEC CE5000-40CRP Service Manual page 31

Ce5000 series
Hide thumbs Also See for CE5000-40CRP:
Table of Contents

Advertisement

¡Enabling/Disabling PEN UP MOVE
This function sets whether the pen will travel to each point specified or only from the initially specified
point to the last specified point when consecutive commands are received specifying pen movement
while it is raised.
When ON is selected, the pen travels consecutively to each coordinate specified by the data received.
When OFF is selected, the pen travels directly from the initially specified point to the last specified point.
(The default setting is OFF.)
¡Enabling/Disabling the Media Sensors
This function sets the media sensors that detect the size of the medium in the feed direction.
When ON is selected, the feed-direction media sensors are enabled.
When OFF is selected, the feed-direction media sensors are disabled.
(The default setting is ON.)
¡Enabling/Disabling the Home Sensors
This function sets the home sensors that detect the width of the medium.
When ON is selected, the home sensors are enabled.
When OFF is selected, the home sensors are disabled.
(The default setting is ON.)
¡Circle-Command Resolution Setting (when the COMMAND setting is HP-GL)
This function sets whether the resolution is automatically set or fixed at a constant 5 degrees when a
cutting-plotter circle command is output while the COMMAND setting is HP-GL.
(The default setting is Auto.)
¡Enabling/Disabling Blade Wear Detection
When ON is selected, the blade wear-detection setting is enabled and the blade wear-detection setting
menu is displayed in the PAUSE menu.
When OFF is selected, the blade wear-detection setting is disabled, and the blade wear-detection setting
menu is removed from the PAUSE menu and is not displayed.
(The default setting is OFF.)
¡Setting the Cross-Cut Force (CE5000-120AP only)
The cross-cut force can be set in the range "1" to "31".
(The default value is 20)
¡PAUSE Key Setting
Selects the screen to be displayed when you press the (PAUSE) key while cutting or plotting.
If you serect "HOLD" the cutting plotter stops cutting or plotting and displays a jobselect screen
prompting you to choose to continue or stop cutting/plotting.
If you serect "MENU" the cutting plotter stops cutting or plotting and displays a pause menu screen.
(The default setting is MENU)