Displaying Sta Switch Settings (Global Settings) - Nortel BES50GE-12T PWR User Manual

50 series business ethernet switch
Table of Contents

Advertisement

106 BES50 administration
Parameter
Multicast Frames
CRC/Alignment Errors
Undersize Frames
Oversize Frames
Fragments
64 Bytes Frames
65-127 Byte Frames
128-255 Byte Frames
256-511 Byte Frames
512-1023 Byte Frames
1024-1518 Byte Frames
1519-1536 Byte Frames

Displaying STA switch settings (global settings)

Use the STA Information page to display a summary of the current bridge
Spanning Tree Algorithm (STA) information that applies to the entire switch.
To open this page from the main menu, choose Applications > Spanning
Tree > STA > Information.
STA Information page items
Item
Spanning Tree State
Bridge ID
Max Age
Copyright © 2006, Nortel Networks
.
Description
The total number of good frames received that were directed to
this multicast address.
The number of CRC/alignment errors (FCS or alignment errors).
The total number of frames received that were less than 64 octets
long (excluding framing bits, but including FCS octets) and were
otherwise well formed.
The total number of frames received that were longer than 1518
octets (excluding framing bits, but including FCS octets) and were
otherwise well formed.
The total number of frames received that were less than 64 octets
in length (excluding framing bits, but including FCS octets) and
had either an FCS or alignment error.
The total number of frames (including bad packets) received and
transmitted that were 64 octets in length (excluding framing bits
but including FCS octets).
The total number of frames (including bad packets) received and
transmitted where the number of octets fall within the specified
range (excluding framing bits but including FCS octets).
Description
Displays if the switch is enabled to participate in an STA-compliant
network.
A unique identifier for this bridge, consisting of the bridge priority,
the MST Instance ID 0, and the MAC address, where the address
is taken from the switch system.
The maximum time (in seconds) a device can wait without
receiving a configuration message before attempting to
reconfigure. All device ports (except for designated ports) should
receive configuration messages at regular intervals. Any port
that ages out STA information (provided in the last configuration
message) becomes the designated port for the attached LAN. If it
is a root port, a new root port is selected from among the device
ports attached to the network.
SMB
Using the Nortel Business Ethernet Switch 50 Series
NN47924-301 01.01 Standard
1.00 October 2006
Nortel Networks Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bes50ge-24t pwrBes50fe-24t pwrBes50fe-12t pwr

Table of Contents