Configuring The Lldp Interfaces; Using The Nortel Business Ethernet Switch 50 Series; Configuring Class Of Service - Nortel BES50GE-12T PWR User Manual

50 series business ethernet switch
Table of Contents

Advertisement

76 BES50 advanced features configuration
Variable
Transmission Interval
(5-32768)
Hold Time Multiplier (2-10)
Delay Interval (0-8192)
Reinitialization Delay (0-10)
Notification Interval (0-3600)
Configuring the LLDP interfaces
Use this procedure to configure the LLDP and Type Length Value (TLV)
settings for each interface.
Procedure steps
Step
1
2
3
Variable definitions
Variable
Admin Status
SNMP Notification
TLV Type
Trunk
Configuring Class of Service
Use these procedures to set the default priority for each interface and to
configure the mapping of frame priority tags to the switch priority queues.
Copyright © 2006, Nortel Networks
.
Value
Type the number (in seconds) between TLV transmissions.
The Transmission Interval must be greater than or equal to
four times the Delay Interval.
Type the time multiplier to hold on to the TLV.
Type the delay time to transmit and receive.
Type the delay time to reinitialize LLDP.
Type the interval time to send a notification.
Action
From the main menu, choose Application > LLDP > Port
Configuration or choose Application > LLDP > Trunk
Configuration.
Select the required setting values for each port and trunk.
Click Submit.
Value
Select the required status. (Transmit [Tx], Receive [Rx], Transmit
and Receive [TxRx], or Disabled.)
Select to enable SNMP notification.
Select the types of information to use in the TLV.
The trunk number.