102 BES50 administration
Item
Admin Key
Oper Key
Admin State,
Oper State

Displaying switch power status

Use the Power Status page to display the Power over Ethernet (PoE)
parameters for the switch. To open this page from the main menu, choose
Configuration > PoE > Power Status.
Power Status page items
Item
Maximum Available Power
System Operation Status
Mainpower Consumption
Thermal Temperature
Software Version
Copyright © 2006, Nortel Networks
.
Description
Current administrative value of the key for the protocol partner.
Current operational value of the key for the protocol partner.
Administrative or operational values of the partner state
parameters:
Expired—The partner receive machine is in the expired state.
Defaulted—The partner receive machine is using defaulted
operational partner information, administratively configured for
the partner.
Distributing—If false, distribution of outgoing frames on this link
is disabled. That is, distribution is currently disabled and is not
expected to be enabled in the absence of administrative changes
or changes in received protocol information.
Collecting—Collection of incoming frames on this link is enabled.
That is, the collection is currently enabled and is not expected to
be disabled in the absence of administrative changes or changes
in received protocol information.
Synchronization—The system considers this link to be IN_SYNC.
That is, it is allocated to the correct Link Aggregation Group, the
group is associated with a compatible aggregator, and the identity
of the Link Aggregation Group is consistent with the system ID
and operational key information transmitted.
Aggregation—The system considers this link to be aggregatable.
That is, the link is a potential candidate for aggregation.
Timeout—Periodic transmission of LACPDUs uses a slow
transmission rate.
LACP-Activity—The activity control value with regard to this link.
(0: Passive; 1: Active)
Description
The configured power budget for the switch.
The PoE power service provided to the switch ports.
The amount of power being consumed by PoE devices connected
to the switch.
The internal temperature of the switch.
The version of software running on the PoE controller subsystem
in the switch.