Lexmark C935 Service Manual page 106

Hide thumbs Also See for C935:
Table of Contents

Advertisement

5057-XXX
Error code or
message
925.00
Service PC
cartridge
925.01
Service PC
cartridge
925.02
Service PC
cartridge
925.03
Service PC
cartridge
930.00
930.01
930.02
930.03
940.00
Service MPF
failure
941.00
Service tray 1
failure
2-14
Printer Service Manual
Error contents
Sensor (Y ATC)
Sensor (M ATC)
Sensor (C ATC)
Sensor (K ATC)
Black toner RFID
communication failure
Cyan toner RFID
communication failure
Magenta toner RFID
communication failure
Yellow toner RFID
communication failure
MPF Tray 5 size sensing
error
Switch (media size) size
sensing error (tray 1)
Description/Action
Outputs of the sensor (Y ATC) are not in the
specified range.
This error must be reset inside diagnostic mode
before troubleshooting or machine operation can
occur.
Go to
"925.00 Sensor (Y ATC)" on page
Outputs of the sensor (M ATC) are not in the
specified range.
This error must be reset inside diagnostic mode
before troubleshooting or machine operation can
occur.
Go to
"925.01 Sensor (M ATC)" on page
Outputs of the sensor (C ATC) are not in the
specified range.
This error must be reset inside diagnostic mode
before troubleshooting or machine operation can
occur.
Go to
"925.02 Sensor (C ATC)" on page
Outputs of the sensor (K ATC) are not in the
specified range.
This error must be reset inside diagnostic mode
before troubleshooting or machine operation can
occur.
Go to
"925.03 Sensor (K ATC)" on page
Communication error with the K sensor (RFID toner
cartridge) has occurred.
Go to
"930.00 Black toner RFID communication
failure" on page
2-110.
Communication error with the C sensor (RFID toner
cartridge) has occurred.
Go to
"930.01 Cyan toner RFID communication
failure" on page
2-111.
Communication error with the M sensor (RFID toner
cartridge) has occurred.
Go to
"930.02 Magenta toner RFID
communication failure" on page
Communication error with the Y sensor (RFID toner
cartridge) has occurred.
Go to
"930.03 Yellow toner RFID communication
failure" on page
2-111.
The MPF size width sensor has failed.
Go to
"940.00 MPF tray 5 size sensing error" on
page
2-112.
The tray 1 switch (media size) detected an invalid
size setting.
Go to
"941.00 Switch (media size) size sensing
error (tray 1)" on page
2-112.
2-108.
2-108.
2-109.
2-110.
2-111.
Previous
Next
Go Back

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents