The 2U Library Configure Library: General Screen - IBM TS3100 Setup, Operator, And Service Manual

Ibm system storage tape library
Table of Contents

Advertisement

Figure 4-23. The 2U library Configure Library: General screen
- Loop: Sequential mode with loop mode ON loads the cartridge in the
lowest numerical slot after the cartridge in the highest numerical slot
has been filled and sent back to its home slot. This allows endless
backup operations without user interaction.
v Active Slots - Select the number of active slots you would like to assign in
your library. This item will affect the number of Res. (Reserved) Slots in
your library. For more information refer to "Configuring I/O Stations and
Reserving Slots" on page 5-78.
Note: Slots can be reserved so that they are invisible to the host. It may be
necessary to reserve slots in order to match the number of available
slots to the ISV software licensing. Slots will be reserved starting with
the highest element address. If your library does not have a dedicated
cleaning cartridge slot, and you desire to enable Auto Clean, you must
designate a reserved slot which can be used to hold the cleaning
cartridge.
v I/O Station Enabled - If checked, the I/O Station is enabled. If not, the first 3
slots (in a 4U library or the 1st slot in a 2U library) are configured as storage.
See "Configure Library: General" on page 5-44.
v Auto Clean Enabled - Automatically cleans drive when drive requests
cleaning and cleaning cartridge is present in a reserved slot or a dedicated
cleaning slot. All cleaning cartridges must have CLN as part of the bar code.
The Universal Cleaning Cartridge has the bar code label CLNUxxLx.
v Bar Code Label Length Reported to Host - Choose between 6 and 8. With 6,
the first six characters of the cartridge VOLSER (Volume Serial Numbers)
will be reported to the host. With 8, All characters in the VOLSER (first six
characters plus the two character media type identifier) will be reported to
the host. For more information on bar code labels, see "Bar Code Label" on
page 6-5.
v Click one of the following:
– Refresh - Click this button to update the current screen.
– Apply Selections - Click this button to submit the changes made to the
screen.
Chapter 4. Installation and Configuration